Infrared Gas Analysis Module
Measures CO, CO2, N2O and CH4.
In-situ and extractive laser gas analyzers configured for process control, emission monitoring and safety applications.
Target gasesSO2, NO, NO2, N2O, O2, CO, CO2, NH3, HCl, HF, CH4, H2O
ConfigurationsIn-Situ, Extractive, Rack-Mount, Analyzer Module
Engineering supportApplication Review, Model Selection, System Integration
Select a gas to compare analyzer models and measurement applications.
| Target Gas | Typical Measurement Task | Available Analyzer Series | Selection Focus |
|---|---|---|---|
| SO2 | Emission Monitoring | ZS9100 | Measuring range, gas composition, system integration |
| NO | Emission Monitoring | ZS9100 | Measuring range, gas composition, system integration |
| NO2 | Emission Monitoring | ZS9100 | Measuring range, gas composition, system integration |
| N2O | Gas Concentration Monitoring | ZS6200 / ZS6500 | Measuring range, gas flow, module or analyzer integration |
| O2 | Combustion / Inerting / Process Safety | ZS8200 / ZS8300 / ZS8500 / ZS9100 | Response time, installation path, process conditions |
| CO | Combustion / Gas Recovery / Process Control | ZS6200 / ZS6500 / ZS8100 / ZS8200 / ZS8300 / ZS8500 / ZS8600 / ZS8700 | Concentration range, safety interlock, integration |
| CO2 | Combustion / Gas Recovery / Process Control | ZS6200 / ZS6500 / ZS8200 / ZS8300 / ZS8500 / ZS8600 / ZS8700 | Concentration range, safety interlock, integration |
| NH3 | Ammonia Slip / DeNOx | ZS8100 / ZS8500 / ZS8600 / ZS8700 / ZS9100 | Low-range measurement, dust, heated sampling, maintenance |
| HCl | Emission Monitoring | ZS8100 / ZS8500 / ZS8600 / ZS8700 | Sample conditioning, gas path, process temperature |
| HF | Emission Monitoring | ZS8100 / ZS8600 / ZS8700 | Sample conditioning, gas path, process temperature |
| CH4 | Greenhouse Gas Detection / Process Safety | ZS6200 / ZS6500 / ZS8200 / ZS8500 | Gas composition, flow, installation environment |
| H2O | Gas Quality | ZS8200 | Gas composition, flow, installation environment |
Choose from in-situ, extractive, rack-mount and module configurations.

Measures CO, CO2, N2O and CH4.

Measures CO, CO2, N2O and CH4.

Extractive laser system for NH3, HCl, HF and CO applications.

Analyzer module for O2, CO2, CO, CH4 and H2O system integration.

Cross-stack measurement of O2, CO and CO2.

19-inch 3U rack-mount analyzer for O2, CO2, CO, CH4, NH3 and HCl.

Multi-pass laser analyzer system covering NH3, CO, CO2, HCl and HF.

Wall-mounted analyzer for NH3, CO, CO2, HCl and HF.

Measures NH3, SO2, NO, NO2 and O2.
Combustion control, ammonia slip, emissions, gas composition and process safety.
Oxygen and carbon monoxide monitoring for combustion adjustment and process control.
Typical models: ZS8200 / ZS8300 / ZS8500Low-range ammonia measurement for SCR/SNCR optimization and ammonia slip monitoring.
Typical models: ZS8100 / ZS8500 / ZS8600 / ZS8700 / ZS9100Stack gas monitoring for sulfur dioxide, nitrogen oxides and acid gases.
SO₂ / NO / NO₂: ZS9100Gas composition and moisture measurement for process monitoring and gas quality control.
N₂O / CO / CO₂ / CH₄: ZS6200 / ZS6500Gas monitoring for inerting control, process alarms and safety interlocks.
Typical models: ZS8200 / ZS8500TDLAS measures gas concentration using a gas-specific laser absorption line. Select the configuration for your process temperature, pressure, dust load and installation.
Laser scans a selected absorption line.
Signal attenuation is related to target gas concentration.
Compensation and diagnostics depend on the model and configuration.
Compare measuring ranges, response times, outputs and operating conditions by model.
Technical proposals, assembly, calibration and commissioning support for your gas analysis project.
Ammonia slip monitoring across five coal-fired boilers using multi-point sampling and TDLAS measurement, with 0.1 ppm-level precision and 300–500°C heat-traced sampling lines.
Four laser gas analyzers were deployed at key gas-recovery points for O2 and CO monitoring, with control-system interlocking for gas recovery safety.
Gas selection, installation, interfaces and technical support.
Send application details →Our analyzers measure SO2, NO, NO2, N2O, O2, CO, CO2, NH3, HCl, HF, CH4 and H2O. Gas availability, measuring range and units depend on the model and configuration.
Choose by process temperature, pressure, dust, moisture, response time and installation space. In-situ analyzers measure directly in the process; extractive systems use a sample gas line.
Target gas, expected range, background gas composition, temperature, pressure, dust, moisture, duct size or optical path, preferred installation method and hazardous-area requirements.
Options include purge, filtration, heated sampling and compensation, depending on the model and process conditions.
RS485 and 4–20 mA outputs are available across multiple models. Relay and switch outputs depend on the analyzer. See the model specifications for interface details.
We provide technical documentation, factory testing and calibration, export packaging, shipping, installation and commissioning guidance, remote support, operator training and spare parts.
Tell us your target gas, measuring range and operating conditions. Our team will help select the analyzer and accessories.
Online inquiry is currently unavailable. Please email or call us to discuss your application.
Email whzshbkj@163.com